    E + H Meter FAQ Analysis and Solution Sharing

     

    Q: How does the output of radar / guidedral belt and how to achieve Double 4-20mA? What variables can be implemented? a) Selection of the output of the switch In addition to a conventional 4-20mA output, there is an attached amount. Settings to generate a working condition for alarm output, easy to monitor measurements. Switch signal output can be set according to the following parameters: • Location • distance • Terminal voltage • Electronic module temperature • Relative echo Note that the switching signal output is the collector path unpacking therefore need to be external. b) Selection of Dual Road 4-20mA Output In addition to the four conventional 4-20mA output, the 2nd road 4-20mA output is added. Settings Similar to the above A). Q: What is the requirements when the capacitors and guidelines measurement interfaces, what is the advantages and disadvantages of the two? Prerequisite for capacitor applications: Two media must be a conductive medium and another non-conductive medium or two media are non-conductive media and their conductivity difference is large; Advantages of Parada Leaders: Safety measurements are not affected by the height of suspension; Disadvantages: The total level height cannot be output; Medium components must be stable. Prerequisite of the application of the wireless radar: The dielectric constant of the upper medium must be a known constant value (the upper layer thickness is known to automatically calculate the dielectric constant by Fieldcare); the dielectric dielectric constant is not greater than 10; the dielectric constant difference between the upper dielectric and the lower dielectric It must be greater than 10; the thickness of the upper medium is at least 80 mm; there is no emulsifying layer. The total level and interface signal can be output simultaneously compared to the capacitance level meter. Disadvantages: Do not adapt to an emulsified layer FMP55 Application Prerequisites: Tommation, but not affected by emulsifying layer Advantages: Combined with the advantages of capacitance and guidedral radar. Question: How does the tirate density implementation? The sensor works based on the principle of component vibration, and the component portion is immersed in the tuning fork portion in the subjected to the liquid. The tuning fork portion is induced by inductive vibration through the inherent pressure appliance fixed to the bottom of the fork. The volatile frequency is detected by the secondary piezoelectric apparatus fixed to the other end of the fork and then enlarges the signal through the top circuit. The liquid density is closely related to the vibration frequency when the liquid flows is subjected to the liquid, and when the density of the liquid is measured, the vibration frequency at the time of liquid flow also changes. By the following equation, the density of the subjected to the liquid can be accurately calculated. D = K0 + K1T + K2T2 D = unclear measured medium density (kg / m3) T = vibration frequency (μs). K0, K1, K2 = constant, reading full text, original title: E + H instrument FAQ and Q & A Article Source: [Micro Signal: HGYBWH, WeChat public number: lazy work control] Welcome to add attention! Please indicate the source of the article.

     

     

     

     

    List all Question

    Nickname

    Email

    Questions

    Our other product:

    Professional FM Radio Station Equipment Package

     



     

    Hotel IPTV Solution

     


      Enter email  to get a surprise

      fmuser.org

      es.fmuser.org
      it.fmuser.org
      fr.fmuser.org
      de.fmuser.org
      af.fmuser.org ->Afrikaans
      sq.fmuser.org ->Albanian
      ar.fmuser.org ->Arabic
      hy.fmuser.org ->Armenian
      az.fmuser.org ->Azerbaijani
      eu.fmuser.org ->Basque
      be.fmuser.org ->Belarusian
      bg.fmuser.org ->Bulgarian
      ca.fmuser.org ->Catalan
      zh-CN.fmuser.org ->Chinese (Simplified)
      zh-TW.fmuser.org ->Chinese (Traditional)
      hr.fmuser.org ->Croatian
      cs.fmuser.org ->Czech
      da.fmuser.org ->Danish
      nl.fmuser.org ->Dutch
      et.fmuser.org ->Estonian
      tl.fmuser.org ->Filipino
      fi.fmuser.org ->Finnish
      fr.fmuser.org ->French
      gl.fmuser.org ->Galician
      ka.fmuser.org ->Georgian
      de.fmuser.org ->German
      el.fmuser.org ->Greek
      ht.fmuser.org ->Haitian Creole
      iw.fmuser.org ->Hebrew
      hi.fmuser.org ->Hindi
      hu.fmuser.org ->Hungarian
      is.fmuser.org ->Icelandic
      id.fmuser.org ->Indonesian
      ga.fmuser.org ->Irish
      it.fmuser.org ->Italian
      ja.fmuser.org ->Japanese
      ko.fmuser.org ->Korean
      lv.fmuser.org ->Latvian
      lt.fmuser.org ->Lithuanian
      mk.fmuser.org ->Macedonian
      ms.fmuser.org ->Malay
      mt.fmuser.org ->Maltese
      no.fmuser.org ->Norwegian
      fa.fmuser.org ->Persian
      pl.fmuser.org ->Polish
      pt.fmuser.org ->Portuguese
      ro.fmuser.org ->Romanian
      ru.fmuser.org ->Russian
      sr.fmuser.org ->Serbian
      sk.fmuser.org ->Slovak
      sl.fmuser.org ->Slovenian
      es.fmuser.org ->Spanish
      sw.fmuser.org ->Swahili
      sv.fmuser.org ->Swedish
      th.fmuser.org ->Thai
      tr.fmuser.org ->Turkish
      uk.fmuser.org ->Ukrainian
      ur.fmuser.org ->Urdu
      vi.fmuser.org ->Vietnamese
      cy.fmuser.org ->Welsh
      yi.fmuser.org ->Yiddish

       
  •  

    FMUSER Wirless Transmit Video And Audio More Easier !

  • Contact

    Address:
    No.305 Room HuiLan Building No.273 Huanpu Road Guangzhou China 510620

    E-mail:
    [email protected]

    Tel / WhatApps:
    +8618078869184

  • Categories

  • Newsletter

    FIRST OR FULL NAME

    E-mail

  • paypal solution  Western UnionBank OF China
    E-mail:[email protected]   WhatsApp:+8618078869184   Skype:sky198710021 Chat with me
    Copyright 2006-2020 Powered By www.fmuser.org

    Contact Us