FMUSER Wirless Transmit Video And Audio More Easier !

[email protected] WhatsApp +8618078869184
Language

    On 3W valuation principles and crosstalk between the traces of

     

    It is said that mathematicians have hated physicists, as mathematician Xin Xin's conclusions are the same as the conclusion that physicists guess. Of course, this is just a joke, but it is indeed an application engineer, it is often necessary to know how it comes to it and its trend, and it is not necessary to completely derive them like a scientist. That let's take a look at the 3W principle, as shown below: The center of the guaranteed cable is greater than the triple line, which is the 3W principle we usually say. In fact, the 3W principle should be changed to the principle of 3h. This h refers to the distance from the reference plane, as shown in the figure, when the trace reaches 3 h, the edge of the static line is very small. Most electromagnetic fields are wrapped between the traces and reflow planes. Here everyone should remember a value. When the trace reaches 3W, the crosstalk rate is about 2% (near-end crosstalk). Some people can't help but ask, do you have different W, as long as it meets 3W principles, is their crosstalk? That's right, their crosstalk rate is really almost. Of course, this is in our usual FR4 material, the impedance is controlled in 50 ohms. If W is reduced, the actual distance between the two lines is coming, but the crosstalk will become large, but to keep 50 ohm impedance, the trace must be closer to the reference plane, so that crosstalk will become smaller. Changes in crosstalk between one chapter have not changed. The case is similar to the case. Remember 3W's crosstalk rate, we just know how much the change in the center of the trace and crosstalk can be estimated to the crosstalk between the traces. Is the central distance change changed to each other between the two lines? Is there a formula for Duang in the brain? The capacitance size is inversely proportional, is it said that the distance is doubled, and the crosstalk minus half? Nonono is a formula for a flat-panel capacitor, but in fact our line is three-dimensional, it should be a distance to n, and crosstalk is 1 / N2. Just like Lorenz, with extraction. Note that the distance here refers to the center distance. Of course, the actual crosstalk is related to the factors such as loss, reflection, dielectric constant, coupling length. However, such an estimated method is also enough to respond to most of the situation. Edit: hfy, read full text

     

     

     

     

    List all Question

    Nickname

    Email

    Questions

    Our other product:

    Professional FM Radio Station Equipment Package

     



     

    Hotel IPTV Solution

     


      Enter email  to get a surprise

      fmuser.org

      es.fmuser.org
      it.fmuser.org
      fr.fmuser.org
      de.fmuser.org
      af.fmuser.org ->Afrikaans
      sq.fmuser.org ->Albanian
      ar.fmuser.org ->Arabic
      hy.fmuser.org ->Armenian
      az.fmuser.org ->Azerbaijani
      eu.fmuser.org ->Basque
      be.fmuser.org ->Belarusian
      bg.fmuser.org ->Bulgarian
      ca.fmuser.org ->Catalan
      zh-CN.fmuser.org ->Chinese (Simplified)
      zh-TW.fmuser.org ->Chinese (Traditional)
      hr.fmuser.org ->Croatian
      cs.fmuser.org ->Czech
      da.fmuser.org ->Danish
      nl.fmuser.org ->Dutch
      et.fmuser.org ->Estonian
      tl.fmuser.org ->Filipino
      fi.fmuser.org ->Finnish
      fr.fmuser.org ->French
      gl.fmuser.org ->Galician
      ka.fmuser.org ->Georgian
      de.fmuser.org ->German
      el.fmuser.org ->Greek
      ht.fmuser.org ->Haitian Creole
      iw.fmuser.org ->Hebrew
      hi.fmuser.org ->Hindi
      hu.fmuser.org ->Hungarian
      is.fmuser.org ->Icelandic
      id.fmuser.org ->Indonesian
      ga.fmuser.org ->Irish
      it.fmuser.org ->Italian
      ja.fmuser.org ->Japanese
      ko.fmuser.org ->Korean
      lv.fmuser.org ->Latvian
      lt.fmuser.org ->Lithuanian
      mk.fmuser.org ->Macedonian
      ms.fmuser.org ->Malay
      mt.fmuser.org ->Maltese
      no.fmuser.org ->Norwegian
      fa.fmuser.org ->Persian
      pl.fmuser.org ->Polish
      pt.fmuser.org ->Portuguese
      ro.fmuser.org ->Romanian
      ru.fmuser.org ->Russian
      sr.fmuser.org ->Serbian
      sk.fmuser.org ->Slovak
      sl.fmuser.org ->Slovenian
      es.fmuser.org ->Spanish
      sw.fmuser.org ->Swahili
      sv.fmuser.org ->Swedish
      th.fmuser.org ->Thai
      tr.fmuser.org ->Turkish
      uk.fmuser.org ->Ukrainian
      ur.fmuser.org ->Urdu
      vi.fmuser.org ->Vietnamese
      cy.fmuser.org ->Welsh
      yi.fmuser.org ->Yiddish

       
  •  

    FMUSER Wirless Transmit Video And Audio More Easier !

  • Contact

    Address:
    No.305 Room HuiLan Building No.273 Huanpu Road Guangzhou China 510620

    E-mail:
    [email protected]

    Tel / WhatApps:
    +8618078869184

  • Categories

  • Newsletter

    FIRST OR FULL NAME

    E-mail

  • paypal solution  Western UnionBank OF China
    E-mail:[email protected]   WhatsApp:+8618078869184   Skype:sky198710021 Chat with me
    Copyright 2006-2020 Powered By www.fmuser.org

    Contact Us